Effective PMI Management with NX Hole Callouts
Working in design engineering with NX, the solution from Siemens Digital Industries Software, provides the functionality of so called "NX hole...
2 min read
Stefanie Ellmer : August 30, 2022
In our article "Effective PMI Management with NX Hole Callouts" we gave a first introduction about NX hole callouts, the associative descriptions/labels for holes and threads, which are created from multiple parameters, derived directly from the hole's feature data. Read in our blog which additioanl parameters are available and how the NX hole callouts are ballooned for inspection.
Since NX1899 there are more parameters available for the individual feature types:
Hole
|
Drill Size Hole
|
Screw Clearance Hole
|
Threaded Hole
|
Symbolic Thread
|
Pattern Feature Count
|
Pattern Feature Count
|
Pattern Feature Count
|
Pattern Feature Count
|
Pattern Feature Count
|
Diameter
|
Diameter
|
Screw Size
|
Thread Size
|
Callout
|
Depth
|
Depth
|
Diameter
|
Thread Depth
|
Length
|
Counter Bore Diameter
|
Size
|
Fit
|
Depth
|
Pitch
|
Counter Bore Depth
|
Start Chamfer Diameter
|
Depth
|
Pitch
|
Angle
|
Counter Sink Diameter
|
Start Chamfer Angle
|
Counter Bore Diameter
|
Angle
|
Minor Diameter
|
Counter Sink Angle
|
|
Counter Bore Depth
|
Minor Diameter
|
Major Diameter
|
Taper Angle
|
|
Counter Sink Diameter
|
Major Diameter
|
Tap Thrill Diameter
|
|
|
Counter Sink Angle
|
Tap Thrill Diameter
|
Shaft Size
|
|
|
Start Chamfer Diameter
|
Start Chamfer Diameter
|
Thread Size
|
|
|
Start Chamfer Angle
|
Start Chamfer Angle |
Thread Pitch
|
|
|
Neck Chamfer Diameter
|
Thread Pitch
|
Internal/External Symbol
|
|
|
Neck Chamfer Angle
|
Internal/External Symbol
|
Thread Direction |
|
|
Relief Chamfer Diameter
|
Thread Direction
|
|
|
|
Relief Chamfer Angle |
A hole callout is a new characteristic type that can be ballooned within BCT Inspector, the quality management solution for NX and Teamcenter. The hole callout characteristic is similar to a text note: the remark column contains the whole callout content as text. Each hole callout / feature type (hole, drill size hole, screw clearance hole, ...) receives one main charateristics number, e.g.
42
FLLs manage additional referenced features of a PMI (Product Manufacturing Information). In the quality process, there is a need to identify and measure each of these elements, identified by its exact position. To fulfill this specification, it is necessary to place identification labels on each of these occurrences (pattern feature count). FLLs will be applied according to number of associated objects on a PMI hole callout, e.g.
F1, F2
Each individual hole callout parameter (FLL, diameter, dimension, angle, note) is assigned a unique sub-balloon number (sub- or integer numbers), taking into account the default tolerances, e.g.
42.1
42.2
The secondary dimension for depth creates an additional Hole Callout for depth. During ballooning it will be handled as a separate hole callout. A new main characteristic number will be assigned, parameter(s) will get sub-numbers assigned. Restriction: if depth parameter is visible on the linear/radial hole callout a separate sub-number will be assigned.
For further information about BCT Add-Ons solutions for Siemens Digital Industries Software just browse our website.
Working in design engineering with NX, the solution from Siemens Digital Industries Software, provides the functionality of so called "NX hole...
Control & Inspection Planning (CP&IP) as part of quality planning is one important module of the Teamcenter Quality solution from Siemens Digital...
Manual processes are time consuming and hold the serious risk of errors. Undisputed one of them is the tracking of design changes: often a manual,...